PETG settings for the Elegoo Centauri Carbon
Last updated 9 November 2026
OrcaSlicer's Generic PETG profile prints at 255 °C, with the bed at 80 °C and the part fan at 20 to 100 %.
| Profile | Nozzle | Bed | Part fan | Max flow | Retraction |
|---|---|---|---|---|---|
| Generic PETG | 255 °C | 80 °C | 20 to 100 % | 10 mm³/s | 0.8 mm |
| Elegoo PETG | 250 °C | 70 °C | 10 to 40 % | 11 mm³/s | 0.8 mm |
| Elegoo PETG PRO | 240 °C | 70 °C | 10 to 40 % | 8 mm³/s | 0.8 mm |
| Elegoo PETG Translucent | 255 °C | 70 °C | 10 to 35 % | 10 mm³/s | 0.8 mm |
| Elegoo PETG-CF | 250 °C | 70 °C | 5 to 40 % | 15 mm³/s | 0.8 mm |
| Elegoo PETG-GF | 250 °C | 70 °C | 5 to 40 % | 12 mm³/s | 0.8 mm |
| Elegoo Rapid PETG | 250 °C | 70 °C | 30 to 80 % | 18 mm³/s | 0.8 mm |
| AliZ PETG | 250 °C | 79 °C | 30 to 80 % | 15 mm³/s | 0.8 mm |
| OrcaSlicer has 40 more PETG profiles for this printer. |
How do I set up my file for the Elegoo Centauri Carbon?
Drop it here. It opens in Convert with the Elegoo Centauri Carbon and Generic PETG picked, and nothing converts until you click Convert.
Which build plate should I use?
Generic PETG sets a bed temperature for each plate:
- Textured PEI plate: 80 °C
- Smooth PEI plate: 80 °C
- Cool plate: 60 °C
- Engineering plate: not supported
- SuperTack plate: 70 °C
Why is my PETG stringing?
Wet PETG strings more, so dry it at 60 to 65 °C for 8 hours (Bambu Lab wiki). If the spool is dry, try 5 to 10 °C below the 255 °C that Generic PETG sets, but not below its 220 °C floor (Prusa Knowledge Base). Keep the part fan on, since cooling PETG prevents stringing, and lengthen retraction (Prusa Knowledge Base).
Why does PETG print so slowly?
Generic PETG caps flow at 10 mm³/s, and the slicer slows any move that would push more plastic than that (slicer source).
Why does my PETG lift or warp?
Generic PETG heats the bed to 80 °C, so clean the sheet first, then add a brim (Prusa Knowledge Base). On smooth PEI, apply a glue stick first, since PETG can bond hard enough to damage the sheet (Prusa Knowledge Base).
Where do these values come from?
From the profiles OrcaSlicer ships, read at OrcaSlicer v2.4.2 (8500fcd). Where a filament profile leaves retraction unset, the table shows the printer profile's value.